The RAYTEK-LMX series of power supplies was newly launched in 2020, featuring high-performance and high-power linear AC power. The linear amplifier in the RAYTEK-LMX series power supply meets the requirements of high peak factor, low distortion, and high fidelity output waveform, making it suitable for demanding AC test power supply applications. The independent model range is from 500 VA to 6 kVA. It can be connected in parallel to expand the power from 8kVA to 30kVA. All models offer single-phase and three-phase modes.
Characteristic
1.USB, LAN (LXI), IEEE-488.2, and RS-232C are compatible with SCPIRAYTEK LSX Series Specification and Model Table
Model | Power (VA) |
Phase | Output (VRSS) | Input (ArSs) | Output phase | Height (U) | Weight (Lbs./KG) |
Single mode phase | |||||||
105LMX | 500 | 1Ø | 135/270 | 4/2 | 1Ø | 3 | 70/31.8 |
108LMX | 750 | 1Ø | 135/270 | 6/3 | 1Ø | 3 | 70/31.8 |
112LMX | 1200 | 1Ø | 150/300 | 10/5 | 1Ø | 3 | 80/36.3 |
140LMX | 4000 | 1Ø | 135/270 | 32/16 | 3Ø | 8 | 185/84.0 |
160LMX | 6000 | 1Ø | 135/270 | 48/16 | 3Ø | 8 | 195/88.6 |
Three mode phase | |||||||
305LMX | 500 | 1Ø 3Ø |
135/270 135 (Vl-N) |
4/2 1.3 per Ø |
1Ø | 3 | 74/33.6 |
308LMX | 750 | 1Ø 3Ø |
135/270 135 (Vl-N) |
6/2 2 per Ø |
1Ø | 3 | 74/33.6 |
312LMX | 1200 | 1Ø 3Ø |
150/300 150 (Vl-N) |
10/3.3 3.3 per Ø |
1Ø | 3 | 80/36.3 |
320LMX | 2000 | 1Ø 3Ø |
135/270 135 (Vl-N) |
18/6 6 per Ø |
3Ø | 5 | 150/68.2 |
345LMX | 4500 | 1Ø 3Ø |
135/270 135 (Vl-N) |
36/12 12 per Ø |
3Ø | 8 | 190/86.3 |
360LMX | 6000 | 1Ø 3Ø |
135/270 135 (Vl-N) |
48/16 16 per Ø |
3Ø | 8 | 195/88.6 |
Model | Power (VA) | Phase | Output voltage (VRMS) |
Output current (Arms) | Input phase | Height (U) | Weight (Lbs./KG) | ||||||
Single mode | Transformer | Transformer | |||||||||||
Direct | 1.5:1 | 2.0:1 | 2.5:1 | Direct | 1.5:1 | 2.0:1 | 2.5:1 | ||||||
105LMXT | 500 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 4/2 | 2.6/1.3 | 2/1 | 1.6/0.8 | 1Ø | 3 | 97/44.0 |
108LMXT | 750 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 6/3 | 4/2 | 3/1.5 | 2.4/1.2 | 1Ø | 3 | 97/44.0 |
140LMXT | 4000 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 32/16 | 21.3/10.7 | 16/8 | 12.8/6.4 | 3Ø | 11 | 310/140.8 |
160LMXT | 6000 | 1Ø/2Ø | 135/270 | 202/404 | 270/540 | 338/600 | 48/16 | 32/10.7 | 24/8 | 19.2/6.4 | 3Ø | 11 | 320/145.4 |
Three | Transformer | Transformer | |||||||||||
Direct | 1.5:1 | 2.0:1 | 2.5:1 | Direct | 1.5:1 | 2.0:1 | 2.5:1 | ||||||
305LMXT | 500 | 1Ø/2Ø 3Ø |
135/270 135/234 |
202/404 202/350 |
270/540 270/468 |
338/600 338/585 |
4 1.3/Ø |
2.6/1.3 1.0/Ø |
2/1 .75/Ø |
1.6/0.8 0.6/Ø |
1Ø | 3 | 100/45.5 |
308LMXT | 750 | 1Ø/2Ø 3Ø |
135/270 135/234 |
202/404 202/350 |
270/540 270/468 |
338/600 338/585 |
6/2 2/Ø |
4/1.3 1.3/Ø |
3/1 1/Ø |
2.4/0.8 0.8/Ø |
1Ø | 3 | 100/45.5 |
320LMXT | 2000 | 1Ø/2Ø 3Ø |
135/270 135/234 |
202/404 202/350 |
270/540 270/468 |
338/600 338/585 |
18/6 6/Ø |
12/4 4/Ø |
9/3 3/Ø |
7.2/2.4 2.4/Ø |
3Ø | 8 | 275/125 |
345LMXT | 4500 | 1Ø/2Ø 3Ø |
135/270 135/234 |
202/404 202/350 |
270/540 270/468 |
338/600 338/585 |
36/12 12/Ø |
24/8 8/Ø |
18/6 6/Ø |
14.4/4.8 4.8/Ø |
3Ø | 11 | 315/143.1 |
360LMXT | 6000 | 1Ø/2Ø 3Ø |
135/270 135/234 |
202/404 202/350 |
270/540 270/468 |
338/600 338/585 |
48/16 16/Ø |
32/10.7 10.7/Ø |
24/8 8/Ø |
19.2/6.4 6.4/Ø |
3Ø | 11 | 320/145.4 |
Output frequency | 15 to 5000Hz full power |
Voltage stabilization rate of input power supply | Maximum 0.1% within ± 10% input range |
load regulation | 0.25% (20 to 2000Hz);0.50% (2000 to 5000Hz);The voltage continuous self calibration function (CSC) can be used to increase it to 0.03%. |
Output distortion rate | 0.1%THD(15 to 1,000Hz), 0.25%THD(1,000 to 5,000Hz). |
Ripple And Noise | -72 dB |
Response time | 5 subtle, typical step load changes |
Output wide band | The general small signal output bandwidth is 5Hz to 50KHz |
Institutional specifications | All models are designed with a 19 inch rack mount. Products with a capacity of 1800VA or above are equipped with handles for easy handling |
Install | Standard 19 inch rack mounted. All models are available for purchasing slide rails. |
Height | Please refer to the model table for panel height |
Depth | The machine body, including wiring terminals, handles, and wiring, should not exceed 24 inches from the front to the back of the machine tool. |
Heat dissipation | The forced air cooling method of blowing air from the front or side and blowing air from the back can dissipate heat. The use of temperature controlled and speed regulated fans can reduce noise and extend fan life. |
Out frequency | 15.00 to 5000Hz±0.01% |
Output voltage (direct coupling) | Programmable control, 0-VSAX, with 0.1V voltage step changes (see table) |
Phase angle | Phase B and C are based on phase A, programmable, 0-359 °, with a resolution of ± 1 ° and an accuracy of ± 0.5 ° |
Current Limit | The current limit can range from zero to the maximum peak current Ipeak of the model, with an accuracy of ± 0.5% and a resolution of ± 10SA. |
Waveform library | It stores 200 waveform libraries that can be edited and executed in any way and at any output phase. |
Voltmeter | Range: 0-340VL-N, 0-600VL-L Resolution: 0.10VAC (front panel), 0.001VAC (remote) Accuracy: ± 0.1% |
Ammeter | Range: 100% rated current Resolution: 0.01AAccuracy: ± (0.5%+f (kHZ) * 0.5%) F S. |
Power meter | Scope: Based on the electrical rangeResolution: 1W or 1VA (front panel), 0.1W or 0.1VA (remote)Accuracy: ± 0.75%, full scale |
Power factor and peak factor | Calculate and display to four significant digits |
Our Customer Support Program provides the training, repair, calibration, and technical support services that our customers value. In addition to receiving the right test equipment, our customers can also count on excellent support before, during and after the sale. With company owned support and service centers around the world, support is never far away. Complete calibration and repair services are offered at our US, European and Chinese manufacturing facili-ties (pls connect customer service ). Calibrations are to original factory specifications and are traceable to NIST (National Institute of Standards and Technology).